temperature range | -20°C to 50°C |
---|---|
temperature accuracy | ±0.21°C from 0°C to 50°C |
temperature resolution | 0.024°C at 25°C |
temperature drift | <0.1°C per year |
Temperature Response Time | 12 minutes to 90% in airflow of 1 m/s (2.2 mph) |
Relative Humidity Range | 1% to 90%, non-condensing |
Relative Humidity Accuracy | ±2% from 20% to 80% RH typical to a maximum of ±4.5% including hysteresis at 25˚C; below 20% RH and above 80% RH ±6% typical |
Relative Humidity Resolution | 0.01% |
Relative Humidity Drift | <0.1% per year typical |
Relative Humidity Response Time | 1 minute to 90% in airflow of 1 m/s (2.2 mph) |
CO2 range | 0 to 5,000ppm |
CO2 accuracy | ±50ppm ±5% of reading at 25°C (77°F), less than 90% RH non-condensing and 1,013mbar |
CO2 warm up time | 15 seconds |
CO2 calibration | Auto or manual to 400ppm |
CO2 Non-linearity | <1% of FS |
CO2 Pressure Dependence | 0.13% of reading per mmHg |
CO2 Operating Pressure Range | 950 to 1,050mbar |
CO2 Compensated Pressure Range | -305 to 5,486 m (-1,000 to 18,000 ft) |
CO2 Sensing Method | Non-dispersive infrared (NDIR) absorption |
CO2 Response Time | 1 minute to 90% in airflow of 1 m/s (2.2 mph) |
Logger | MX1102A |
Radio Power | 1 mW (0 dBm) |
Transmission range | Approximately 30.5 m (100ft) line-of-sight |
Wireless Data Standard | Bluetooth Smart (Bluetooth Low Energy, Bluetooth 4.0) |
Operating range | -20° to 50°C; 0 to 95% RH (non-condensing) |
Logging rate | 1 second to 18 hours |
Logging Modes | Fixed interval (normal, statistics) or burst |
Memory Modes | Wrap when full or stop when full |
Start Modes | Immediate, push button, date & time, or next interval |
Stop Modes | When memory full, push button, date & time, or after a set logging period |
Time Accuracy | ± 1 minute per month at 25°C |
Power Source | 4 AA 1.5 Volt batteries (user replaceable) or USB power source (5 V DC, 2 Watts) |
Battery Life | 6 months, typical with logging and sampling intervals of 5 minutes or slower; 6 months or less with logging and sampling intervals faster than 5 minutes while logging CO2. Entering burst logging mode will impact battery life. With HOBOmobile use, battery life can be reduced by remaining connected, excessive readouts, checking of Full Status Details, audible alarms, and paging. Visual/audible alarms and other events can have a marginal impact on battery life. |
Memory | 128 KB (84,650 measurements, maximum) |
Download Type | USB 2.0 interface or via Bluetooth Smart |
LCD | LCD is visible from 0° to 50°C; the LCD may react slowly or go blank in temperatures outside this range |
Size | 7.62 x 12.95 x 4.78cm |
Weight | 267.4g |
Full Memory Download Time | 20 seconds via USB; approximately 60 seconds via Bluetooth Smart, may take longer the further the device is from the logger |
Environmental Rating | IP 50 |
CE | The CE Marking identifies this product as complying with all relevant directives in the European Union (EU). |
HOBO MX1102A Bluetooth Low Energy Carbon Dioxide/Temperature/Relative Humidity Data Logger
Overview:
Onset’s HOBO MX1102A CO2 logger makes it more convenient than ever to measure and record CO2 in buildings and other non-condensing environments. It measures CO2 from 0-5,000 parts per million (ppm) and our free HOBOmobile app* allows you to access data right from your mobile phone or tablet within a 100-foot range.
The MX1102A also features a USB port so it can be used with a computer running HOBOware graphing and analysis software.
Highlight:
- Wireless communication via Bluetooth Low Energy (BLE) Technology
- Six month battery life at 5-minute CO2 logging rate
- Easy to deploy and offload using free HOBOmobile App
- Visual and audible high & low alarm thresholds
- Self-calibrating NDIR CO2 sensor technology ensures optimal accuracy and lower maintenance costs
- Memory up to 84,650 measurements
- Patented connectivity technology