Model / Dimension (mm) | Model 1: MSC 800 Model 2: MSC 1200 Model 3: MSC 1800 |
---|---|
Air Cleanliness | > ISO Class 4 (Class 10) |
Primary Filter | H14 HEPA Filter, 99.97% efficient at 0.3 micron |
Secondary Filter | H14 HEPA Filter, 99.97% efficient at 0.3 micron |
Aperture Height | 200 mm |
Downflow Velocity (m3/hr @ m/sec) | Model 1 : 492 m3/hr @0.38 m/sec |
Inflow Velocity (m3/hr @ m/sec) | Model 1 : 390 m3/hr @0.77 m/sec |
Construction | Epoxy coated Zintec Mild Steel. Toughened Glass Panels. Removable, Sectional 316 Stainless Steel Work Surface |
Power | Model 1 : 150 Watts |
Weight | Model 1 : 135 kg |
Class II Biological Safety Cabinet, Type A2
Guardian® Class II Biological Safety Cabinets
Guaranteed Product, Personnel And Environmental Protection.
The Class II Biological Safety Cabinet utilises a specially ventilated enclosure, developed for sterile material handling. The unit guarantees both the operator and the working materials protection from potential biohazard infections.
Standard Features include:
- Low Energy < 120watts of power.
- UV Lighting Strip ensures VHP & Formalin Disinfection.
- Electric Sash Adjustment & Closure.
- H 14 HEPA Filter creates an ISO Class 4 Clean Environment.
- Air Diffuser and Sloped Intake for efficient and smooth airflow.
- Removable Polished Stainless Steel Work Surface.
The Guardian range is fitted with the Visionaire® 4.3” full colour touch screen control system that allows the highest level of control and monitoring. Alongside the standard Touchscreen features the Guardian system incorporates; a Visual Display of Inlet and Downward Air Velocity (m/sec or ft/min), Sash Adjustment, Control for: UV Light, Electrical Socket, Cabinet Power and Light Variable intensity. Audible and Visual alarms alert the user to maintenance requirements including: Service, UV Light replacement and Cabinet Hours Run. Formalin and VHP Cycles are also controllable.
Infra-Red Intelligent Sash Safety (IRISS)
The system is also fitted with our unique Infra-Red Intelligent Sash Safety (IRISS) system which projects an infra-red beam across the base of the opening, should this beam be broken by inadvertently positioned apparatus or an operator’s hand, the door closure will be instantly and automatically aborted, preventing potential injuries, instrument damage or sash damage.
The Guardian Micro-Biological Safety Cabinet has been independently type tested and approved to BS EN 12469:2000 by the UK’s leading authority on BioSafety Cabinets, the Health Protection Agency